EMC Celerra FAQ’s

Posted: March 31, 2010 in Celerra

Over the last couple of months Ive had a fair number of questions from readers wanting to know more about the EMC Celerra, there are a few common questions which keep coming up so I thought it would be worth doing a post to try to answer some of the FAQ’s.

 Does Celerra support EFD (Solid State) disks ?

 Absolutely !

The following raid configurations are supported

  • 8+1 Raid 5
  • 4+1 Raid 5
  • 2+2 Raid 1/0

Is the Celerra really just a Clariion with NAS functionality ?

The Celerra does indeed use the Clariion for the storage layer, which of course is one of the reasons its such a beast. The NAS functionality comes via FC connected datamovers (blades) which can be seen in the image below. Note each datamover is connected to both storage processors, everything about the Celerra screams high availability.

What protocols does the Celerra support ?

The Celerra is EMC’s unified storage platform, whatsunified storage all about you ask ? Well simply put it means the Celerra can provision storage using any of the following storage protocols CIFS, NFS, ISCSI, as well as  FC.

The image below shows the Celerra presenting storage to an ESX host using all three VMware supported storage protocols.

You may have noticed in the list of protocols CIFS was listed, you might be wondering why you would use this functionality within a Virtual Infrastructure, keep an eye out for up coming posts as ill be covering this.

How many network interfaces does the datamover have ?

The first image shows the datamover with 4 copper ethernet ports. All ports are 10/100/1000

The second image below shows the newer 10GB model which become availalble end of 2009. The datamover has two copper 10/100/1000 ports and two optical 10GB ports.

When it comes to networking there are typically two things people ask about, Performance and High Availibility.

If required the ports can be aggregated together to create a single logical device using either EtherChannel or LACP. The key thing to remember here is this does not automatically increase bandwidth. I was planning on going into this with much more detail but I remembered Jason Nash has already done a great post on fault tolerant Celerra networking so rather than repeat the same information, check out his post here.

Can I have two active datamovers ?

In higher end models with additional datamovers you may decide to have 2 or more active datamovers with another configured in standby mode. For models which only support two datamovers, while it is technically possible………… don’t do it ! 

A Celerra with only 2 datamovers (blades) should always be configured active/standby.

Is iSCSI off the datamover true block ?

No each iSCSI lun is actually configured within a file system, so here the Celerra uses emulation. If you want true native block you’ll need to order additional iSCSI modules for the storage processors. The image below shows additional iSCSI modules in slots A1,A2 and B1,B2.

Whats the difference between Integrated, FC and Gateway models ?

NS120 Integrated –

The image below shows the storage processor for an integrated unit. The first module is the management module which is common across integrated and FC models. Port 2 and 3 on each storage processor are used to connect the datamovers (blades), port 1 is disabled (on the NS120)  and port 0 connects the storage processor to the LCC controller on the disk enclosure.

An integrated system essentially means the backend Clariion is dedicated to the datamovers, you don’t have spare FC front end ports to allow additional hosts to be connected. All management is done using Celerra Manager.

NS120 FC Enabled –

Looking at the image below, the first thing you’ll notice is now we have an additional FC module in each storage processor. The additional ports can be used to either directly connect hosts, or can be connected to a switched storage area network.

An FC enabled system allows you to present storage from the Clariion to the Celerra datamovers, as well as other FC connected hosts. Management is done using Celerrra Manager and Navisphere Manager.

Gateway –

At this time I dont have an image showing the Celerra gateway, but essentially the gateway consists of the datamover and control station components. The datamovers are connected to an existing Clariion or Symmetrics storage array.

Advertisements
Comments
  1. Ajay says:

    So if i get this right, the Celerrat Unified Storage model, can export a File share (NAS) as well as a block storage (a SAN LUN) . correct?

  2. Jason Boche says:

    The Celerra provides CIFS, NFS/NAS, and iSCSI via the DataMovers. It also provides FC and iSCSI native block storage (assuming these modules are installed).

    Configuring the different storage types is done across 2 tools:

    Celerra Manager (handles CIFS, NFS, and iSCSI via the DataMovers, as well as all the features surrounding these protocols such as virtual provisioning, dedupe, replication, etc.)

    NaviSphere (handles FC storage, and I’m guessing native hardware iSCSI with the appropriate modules – I don’t have them so I don’t know for sure)

  3. Adrian says:

    Hi There, we have a NS20 and were going to deploy; however from what I gather there is no way to have data deduplication. It is worth holding out and use a NS-120 instead?

    – Adrian

    • Brian Norris says:

      Hi Adrian.

      You absolutely can have dedup enabled on the NS20. This feature was introduced with a DART upgrade and typically doesn’t cost you a cent if your hardware is under maintenance.
      Regards
      Brian

  4. Adrian says:

    Hi Brian,

    Thanks for the follow up. We have purchased a NS-120 unit however it does not have the vault pack drives.

    I was hoping I could replace the NS20 head with the NS-120 unit but on further investigation it looks like this may be not possible.

    Can I upgrade the NS20 vault pack so its compatible with the NS-120. I noticed the NS-120 runs 64bit OS.

    – Adrian

  5. Adrian says:

    In answer to my own question:

    >>Can I upgrade the NS20 vault pack so its compatible with the NS-120. I noticed the NS-120 runs 64bit OS.

    Yes, you can you need the Conversion Prep/Image & the RecoveryImage. This is available as a conversion pack from EMC.

  6. mejon2 says:

    Hello,
    Very interresting blog !
    I have 2 questions, wich RAID configurations are supported by the Celerra, and what is the maximum LUN size for the Celerra.
    I found this, this is already good ?
    Thanks 🙂

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s